10 kW hand truck power station
What you need
- View on Amazon
A 48 V all-in-one inverter: inverter, two solar charge controllers and a battery charger in one box, putting out 120 V on each leg and 240 V across both.
Explanation
- The heart of Will Prowse's 10 kW hand truck. It screws to the back of the hand truck frame, over the wheels.
- It needs at least 125 V on each solar input to charge, so panels go in series. It takes a 240 V, 4-wire source (NEMA 14-50) on its AC input; a 120 V source gives a fault.
Tech specs
Solar inputs 2 Input voltage 125–500 V; never above 500 V open-circuit Full-power voltage 125–425 V Current per input 22 A Power per input 5,000 W AC output 10,000 W, 120/240 V split phase; 20,000 W peak, rated for 6 HP motors Solar Two inputs, 10,000 W together, up to 22 A each; 125 to 425 V working range, 500 V open-circuit maximum Battery 48 V, not included; charges at up to 200 A Weight About 54 to 60 lb Figures from Will Prowse's build page and the Amazon listing.
Suggested setups
Panel Wiring per input Voltage(When cold) Current Max power(Per input) All inputs String fuse HQST 200W N-Type solar panel 20 in seriesany 7 to 20 in series works 493 V limit 500 V 11 A limit 22 A 4,000 W 8,000 W 40 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. HQST 200W N-Type solar panel 19 in seriesany 7 to 19 in series works 485 V limit 500 V 11 A limit 22 A 3,800 W 7,600 W 38 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. HQST 200W N-Type solar panel 18 in seriesany 7 to 18 in series works 476 V limit 500 V 11 A limit 22 A 3,600 W 7,200 W 36 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. HQST 200W N-Type solar panel 18 in seriesany 7 to 18 in series works 488 V limit 500 V 11 A limit 22 A 3,600 W 7,200 W 36 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. HQST 200W N-Type solar panel 17 in seriesany 7 to 17 in series works 476 V limit 500 V 11 A limit 22 A 3,400 W 6,800 W 34 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. Renogy 200W N-Type solar panels (4-pack, 800 W) 3 strings of 9 in series, joined with a fuse on each string 371 V limit 500 V 20.5 A limit 22 A 5,000 W 10,000 W 54 panels, 2 inputs 15 A on each stringThe other strings can overload a faulted one. Renogy 200W N-Type solar panels (4-pack, 800 W) 3 strings of 9 in series, joined with a fuse on each string 384 V limit 500 V 20.5 A limit 22 A 5,000 W 10,000 W 54 panels, 2 inputs 15 A on each stringThe other strings can overload a faulted one. Renogy 200W N-Type solar panels (4-pack, 800 W) 3 strings of 9 in series, joined with a fuse on each string 398 V limit 500 V 20.5 A limit 22 A 5,000 W 10,000 W 54 panels, 2 inputs 15 A on each stringThe other strings can overload a faulted one. Renogy 200W N-Type solar panels (4-pack, 800 W) 3 strings of 9 in series, joined with a fuse on each string 408 V limit 500 V 20.5 A limit 22 A 5,000 W 10,000 W 54 panels, 2 inputs 15 A on each stringThe other strings can overload a faulted one. Renogy 200W N-Type solar panels (4-pack, 800 W) 3 strings of 9 in series, joined with a fuse on each string 421 V limit 500 V 20.5 A limit 22 A 5,000 W 10,000 W 54 panels, 2 inputs 15 A on each stringThe other strings can overload a faulted one. ZOUPW 450W portable solar panel 9 in seriesany 4 to 9 in series works 454 V limit 500 V 12.4 A limit 22 A 4,050 W 8,100 W 18 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W portable solar panel 9 in seriesany 4 to 9 in series works 471 V limit 500 V 12.4 A limit 22 A 4,050 W 8,100 W 18 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W portable solar panel 9 in seriesany 4 to 9 in series works 487 V limit 500 V 12.4 A limit 22 A 4,050 W 8,100 W 18 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W portable solar panel 9 in seriesany 4 to 9 in series works 500 V limit 500 V 12.4 A limit 22 A 4,050 W 8,100 W 18 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W portable solar panel 8 in seriesany 4 to 8 in series works 459 V limit 500 V 12.4 A limit 22 A 3,600 W 7,200 W 16 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W PRO bifacial portable solar panel 9 in seriesany 4 to 9 in series works 455 V limit 500 V 12.4 A limit 22 A 4,050 W 8,100 W 18 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W PRO bifacial portable solar panel 9 in seriesany 4 to 9 in series works 472 V limit 500 V 12.4 A limit 22 A 4,050 W 8,100 W 18 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W PRO bifacial portable solar panel 9 in seriesany 4 to 9 in series works 489 V limit 500 V 12.4 A limit 22 A 4,050 W 8,100 W 18 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W PRO bifacial portable solar panel 8 in seriesany 4 to 8 in series works 445 V limit 500 V 12.4 A limit 22 A 3,600 W 7,200 W 16 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. ZOUPW 450W PRO bifacial portable solar panel 8 in seriesany 4 to 8 in series works 460 V limit 500 V 12.4 A limit 22 A 3,600 W 7,200 W 16 panels, 2 inputs Not neededOne string can't overload itself. If you add one anyway: 20 A. Worked out from the figures under Tech specs, with the cold-weather voltage factors of NEC Table 690.7(A). Too much voltage can destroy a power station or inverter: stay under the limit, and use one model of panel in each string.
- View on Amazon
A 48 V lithium (LiFePO4) server-rack battery that stores 5,120 Wh, for a 48 V inverter such as the EG4.
Tech specs
Battery 100 Ah at 51.2 V, 5,120 Wh LiFePO4 Expansion Up to 32 in parallel (163.8 kWh) Inverter communication CAN and RS485 (closed loop) Monitoring Bluetooth and Wi-Fi app Certifications UL9540, UL9540A, UL1973, CEC listed Included Parallel, communication and grounding cables, terminal covers, screws Size and weight 22.09 × 19.02 × 5.63 in, 103 lb; fits a server rack Warranty 10 years Idle draw Not published (BMS, Bluetooth and Wi-Fi) Figures from the Amazon listing.
- View at Home Depot
A steel hand truck rated for 1,000 lb, with a wide toe plate and flat-free tires.
Explanation
The frame of the 10 kW hand truck. Both batteries stand upright on the toe plate with a ratchet strap around them, the outlet box screws to the frame above them and the inverter to the back. The finished gear weighs about 270 lb.
- View at Current Connected
Battery cables made to the length you order, with lugs crimped on both ends.
Explanation
The 10 kW hand truck needs four in 2/0 AWG with 5/16 in (M8) lugs on both ends: red 2 ft and black 2 ft from the batteries to the inverter, and a red 1 ft and a black 1 ft jumper between the two batteries.
- View on Amazon
A weatherproof box with a 50 A 14-50R, a 30 A TT-30R and 20 A 5-20R outlets, each on its own breaker.
Explanation
Takes the place of a load panel on the 10 kW hand truck: wired to the inverter's AC output, it gives 240 V for a well pump, dryer, 50 A RV or EV charger, plus 120 V outlets.
- View on Amazon
Four color-coded 5 ft lengths of stranded THHN building wire: three 6 AWG and a 10 AWG green ground.
Explanation
Connects the outlet box to the inverter's AC output on the 10 kW hand truck: black to L1, red to L2, white to neutral, green to ground.
Tech specs
Wires 6 AWG black, red and white; 10 AWG green; 5 ft each Rating 600 V, 19 strands Figures from the Amazon listing.
- View on Amazon
A 30 A, 2-pole DC breaker in a weatherproof box that switches a solar string off, with short MC4 leads.
Explanation
Each solar string on the 10 kW hand truck runs through its own disconnect to the inverter; a second string needs a second one.
- View on Amazon
A 3 ft 50 A plug cord with open wire ends, for hardwiring a 240 V input.
Explanation
Optional on the 10 kW hand truck: it connects the inverter's AC input to a 240 V, 4-wire source (a 14-50 outlet or a generator) for charging.
- View on Amazon
A red and a black 20 ft, 10 AWG solar cable with MC4 connectors.
Explanation
Optional on the 10 kW hand truck: use it if your panel leads don't reach the PV disconnect.
- View on Amazon
Heavy-duty hand cutters for copper cable.
Explanation
Cuts the NEMA 14-50 cord and the 6 AWG THHN for the 10 kW hand truck.
- View on Amazon
A wire stripper that adjusts itself to wire from 10 to 24 AWG.
Explanation
Strips the NEMA 14-50 cord and the 10 AWG PV wire for the 10 kW hand truck.
- View on Amazon
A ratchet crimper with a hex die and a box of ferrules in 17 sizes.
Explanation
A ferrule turns stranded wire into one solid pin that a screw terminal can grip. On the 10 kW hand truck one goes on every stranded wire into a screw terminal: the AC input cord, the AC output wires to the outlet box and the two PV wires.
- View on Amazon
An assortment of hex-head self-drilling screws for sheet metal, 1/2 in to 1-1/4 in.
Explanation
Mounts the inverter bracket, the outlet box and the PV disconnect to the hand truck frame.
This is Will Prowse’s build from his video Stop Buying Solar Generators. Build This 10kW Hand Truck in One Day. His full build page, with the wiring diagram, inverter settings, startup order, solar string table and fault codes, is here: 120/240V 10kW Budget Hand Truck. Follow his page when you build it; this page gathers the parts.
What it is
One 10,000 W split-phase all-in-one inverter and two 48 V server-rack batteries on a steel hand truck. It puts out 120 V and 240 V, so it can run a well pump, a dryer, a 50 A RV or an EV charger. Roll it to where you need power, plug in solar panels or a 240 V source, and run loads from its outlet box.
- 10,000 W at 120/240 V, 20,000 W peak
- 10,240 Wh of LiFePO4 battery (two Cubix 100; buy two)
- Up to 10,000 W of solar on two inputs
- Charges from solar or a 240 V, 4-wire source (NEMA 14-50)
- About 270 lb of gear, already on wheels
What else you need
- Solar panels, wired in series: the inverter needs at least 125 V on each input to charge. Will’s page has a table of how many panels per string.
- PV wire from your panels, and a second PV disconnect if you run a second string.
- A ratchet strap around both batteries (any hardware store).
How it goes together
Both batteries stand upright on the hand truck’s toe plate, the outlet box screws to the frame above them, and the inverter screws to the back over the wheels. The wiring is four battery cables, two AC connections (input cord and outlet box) and up to two solar strings. Turn both batteries off before making any connection, and follow Will’s startup order and settings, including turning on the inverter’s neutral-to-ground bond.
Electricity can kill. If you are not sure about any step, have an electrician check your work.