Just a theory, but it may begin November 25th. The time to prepare is largely over; supplies are selling out. Guides will be updated when possible.

All supply lists

Power

Solar

Buy panels before December 4, 2026. From that date imported solar panels carry a new 15% tariff and a minimum import price, and analysts expect prices to rise. Until December 3 a Commerce Department rule stops importers from bringing in more panels than usual ahead of the tariff. The rule limits importers, not you.

  1. Tariff from Dec 4

    A single rigid 200 W solar panel for a fixed mount.

    View on Amazon
    Tech specs
    Maximum power200 W
    Working voltage (Vmp)19.02 V
    Working current (Imp)10.5 A
    Open-circuit voltage (Voc)22.4 V
    Short-circuit current (Isc)11.04 A
    Maximum series fuse20 A
    System type12 V
    Size46.3 × 30.1 × 1.2 in
    Weight20.2 lb

    Figures from the Amazon listing.

    Suggested setups
    IntoWiring per inputVoltage(When cold)CurrentMax power(Per input)All inputsString fuse
    Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh)6 in seriesany 1 to 6 in series works148 V limit 165 V11 A limit 17 A1,200 W2,400 W 12 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh)6 in seriesany 1 to 6 in series works153 V limit 165 V11 A limit 17 A1,200 W2,400 W 12 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh)6 in seriesany 1 to 6 in series works159 V limit 165 V11 A limit 17 A1,200 W2,400 W 12 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh)6 in seriesany 1 to 6 in series works163 V limit 165 V11 A limit 17 A1,200 W2,400 W 12 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh)5 in seriesany 1 to 5 in series works140 V limit 165 V11 A limit 17 A1,000 W2,000 W 10 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    EG4 6000XP off-grid inverter (6,000 W, 120/240 V)19 in seriesany 7 to 19 in series works468 V limit 480 V11 A limit 25 A3,800 W7,600 W 38 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    EG4 6000XP off-grid inverter (6,000 W, 120/240 V)18 in seriesany 7 to 18 in series works460 V limit 480 V11 A limit 25 A3,600 W7,200 W 36 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    EG4 6000XP off-grid inverter (6,000 W, 120/240 V)18 in seriesany 7 to 18 in series works476 V limit 480 V11 A limit 25 A3,600 W7,200 W 36 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    EG4 6000XP off-grid inverter (6,000 W, 120/240 V)17 in seriesany 7 to 17 in series works461 V limit 480 V11 A limit 25 A3,400 W6,800 W 34 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    EG4 6000XP off-grid inverter (6,000 W, 120/240 V)17 in seriesany 7 to 17 in series works476 V limit 480 V11 A limit 25 A3,400 W6,800 W 34 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    SunGold Power 10,000 W split-phase solar inverter (SPH10048P)20 in seriesany 7 to 20 in series works493 V limit 500 V11 A limit 22 A4,000 W8,000 W 40 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    SunGold Power 10,000 W split-phase solar inverter (SPH10048P)19 in seriesany 7 to 19 in series works485 V limit 500 V11 A limit 22 A3,800 W7,600 W 38 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    SunGold Power 10,000 W split-phase solar inverter (SPH10048P)18 in seriesany 7 to 18 in series works476 V limit 500 V11 A limit 22 A3,600 W7,200 W 36 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    SunGold Power 10,000 W split-phase solar inverter (SPH10048P)18 in seriesany 7 to 18 in series works488 V limit 500 V11 A limit 22 A3,600 W7,200 W 36 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    SunGold Power 10,000 W split-phase solar inverter (SPH10048P)17 in seriesany 7 to 17 in series works476 V limit 500 V11 A limit 22 A3,400 W6,800 W 34 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    Victron SmartSolar MPPT 100/50 charge controller4 in seriesany 2 to 4 in series works99 V limit 100 V11 A limit 60 A700 W700 W 4 panels, 1 inputNot neededOne string can't overload itself. If you add one anyway: 20 A.
    Victron SmartSolar MPPT 100/50 charge controller2 strings of 2 in series, joined with a 2-to-1 Y connector51 V limit 100 V22.1 A limit 60 A700 W700 W 4 panels, 1 inputNot neededThe other string can feed at most 14 A, within the panel's 20 A rating. If you add one anyway: 20 A.
    Victron SmartSolar MPPT 100/50 charge controller2 strings of 2 in series, joined with a 2-to-1 Y connector53 V limit 100 V22.1 A limit 60 A700 W700 W 4 panels, 1 inputNot neededThe other string can feed at most 14 A, within the panel's 20 A rating. If you add one anyway: 20 A.
    Victron SmartSolar MPPT 100/50 charge controller2 strings of 2 in series, joined with a 2-to-1 Y connector54 V limit 100 V22.1 A limit 60 A700 W700 W 4 panels, 1 inputNot neededThe other string can feed at most 14 A, within the panel's 20 A rating. If you add one anyway: 20 A.
    Victron SmartSolar MPPT 100/50 charge controller2 strings of 2 in series, joined with a 2-to-1 Y connector56 V limit 100 V22.1 A limit 60 A700 W700 W 4 panels, 1 inputNot neededThe other string can feed at most 14 A, within the panel's 20 A rating. If you add one anyway: 20 A.

    Worked out from the figures under Tech specs, with the cold-weather voltage factors of NEC Table 690.7(A). Too much voltage can destroy a power station or inverter: stay under the limit, and use one model of panel in each string.

  2. Tariff from Dec 4

    Four rigid 200 W solar panels (800 W in all) for a fixed mount on a roof, rack or the ground.

    View on Amazon
    Tech specs
    Maximum power200 W
    Working voltage (Vmp)31.03 V
    Working current (Imp)6.46 A
    Open-circuit voltage (Voc)37.44 V
    Short-circuit current (Isc)6.85 A
    Maximum series fuse15 A
    Panels in the pack4 (figures above are per panel)
    System type24 V
    Size49.7 × 30.1 × 1.2 in
    Weight93.6 lb for the four

    Figures from the Amazon listing.

    Suggested setups
    IntoWiring per inputVoltage(When cold)CurrentMax power(Per input)All inputsString fuse
    Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh)2 strings of 4 in series, joined with a 2-to-1 Y connector165 V limit 165 V13.7 A limit 17 A1,600 W3,200 W 16 panels, 2 inputs per F3800 Plus unitNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh)2 strings of 3 in series, joined with a 2-to-1 Y connector128 V limit 165 V13.7 A limit 17 A1,200 W2,400 W 12 panels, 2 inputs per F3800 Plus unitNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh)2 strings of 3 in series, joined with a 2-to-1 Y connector133 V limit 165 V13.7 A limit 17 A1,200 W2,400 W 12 panels, 2 inputs per F3800 Plus unitNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh)2 strings of 3 in series, joined with a 2-to-1 Y connector136 V limit 165 V13.7 A limit 17 A1,200 W2,400 W 12 panels, 2 inputs per F3800 Plus unitNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh)2 strings of 3 in series, joined with a 2-to-1 Y connector140 V limit 165 V13.7 A limit 17 A1,200 W2,400 W 12 panels, 2 inputs per F3800 Plus unitNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    EG4 6000XP off-grid inverter (6,000 W, 120/240 V)2 strings of 10 in series, joined with a 2-to-1 Y connector412 V limit 480 V13.7 A limit 25 A4,000 W8,000 W 40 panels, 2 inputsNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    EG4 6000XP off-grid inverter (6,000 W, 120/240 V)2 strings of 10 in series, joined with a 2-to-1 Y connector427 V limit 480 V13.7 A limit 25 A4,000 W8,000 W 40 panels, 2 inputsNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    EG4 6000XP off-grid inverter (6,000 W, 120/240 V)2 strings of 10 in series, joined with a 2-to-1 Y connector442 V limit 480 V13.7 A limit 25 A4,000 W8,000 W 40 panels, 2 inputsNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    EG4 6000XP off-grid inverter (6,000 W, 120/240 V)2 strings of 10 in series, joined with a 2-to-1 Y connector453 V limit 480 V13.7 A limit 25 A4,000 W8,000 W 40 panels, 2 inputsNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    EG4 6000XP off-grid inverter (6,000 W, 120/240 V)2 strings of 10 in series, joined with a 2-to-1 Y connector468 V limit 480 V13.7 A limit 25 A4,000 W8,000 W 40 panels, 2 inputsNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    SunGold Power 10,000 W split-phase solar inverter (SPH10048P)3 strings of 9 in series, joined with a fuse on each string371 V limit 500 V20.5 A limit 22 A5,000 W10,000 W 54 panels, 2 inputs15 A on each stringThe other strings can overload a faulted one.
    SunGold Power 10,000 W split-phase solar inverter (SPH10048P)3 strings of 9 in series, joined with a fuse on each string384 V limit 500 V20.5 A limit 22 A5,000 W10,000 W 54 panels, 2 inputs15 A on each stringThe other strings can overload a faulted one.
    SunGold Power 10,000 W split-phase solar inverter (SPH10048P)3 strings of 9 in series, joined with a fuse on each string398 V limit 500 V20.5 A limit 22 A5,000 W10,000 W 54 panels, 2 inputs15 A on each stringThe other strings can overload a faulted one.
    SunGold Power 10,000 W split-phase solar inverter (SPH10048P)3 strings of 9 in series, joined with a fuse on each string408 V limit 500 V20.5 A limit 22 A5,000 W10,000 W 54 panels, 2 inputs15 A on each stringThe other strings can overload a faulted one.
    SunGold Power 10,000 W split-phase solar inverter (SPH10048P)3 strings of 9 in series, joined with a fuse on each string421 V limit 500 V20.5 A limit 22 A5,000 W10,000 W 54 panels, 2 inputs15 A on each stringThe other strings can overload a faulted one.
    Victron SmartSolar MPPT 100/50 charge controller2 strings of 2 in series, joined with a 2-to-1 Y connector82 V limit 100 V13.7 A limit 60 A700 W700 W 4 panels, 1 inputNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    Victron SmartSolar MPPT 100/50 charge controller2 strings of 2 in series, joined with a 2-to-1 Y connector85 V limit 100 V13.7 A limit 60 A700 W700 W 4 panels, 1 inputNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    Victron SmartSolar MPPT 100/50 charge controller2 strings of 2 in series, joined with a 2-to-1 Y connector88 V limit 100 V13.7 A limit 60 A700 W700 W 4 panels, 1 inputNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    Victron SmartSolar MPPT 100/50 charge controller2 strings of 2 in series, joined with a 2-to-1 Y connector91 V limit 100 V13.7 A limit 60 A700 W700 W 4 panels, 1 inputNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    Victron SmartSolar MPPT 100/50 charge controller2 strings of 2 in series, joined with a 2-to-1 Y connector94 V limit 100 V13.7 A limit 60 A700 W700 W 4 panels, 1 inputNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.

    Worked out from the figures under Tech specs, with the cold-weather voltage factors of NEC Table 690.7(A). Too much voltage can destroy a power station or inverter: stay under the limit, and use one model of panel in each string.

  3. Tariff from Dec 4

    A portable 450 W solar panel that you set out in the sun and plug into a power station or charge controller.

    Explanation
    • If you're not an electrician, portable panels are much harder to get wrong.
    • Buy all the panels you'll need at once, of one model: mismatched panels wired together drag each other down. Check your power station's solar input limits first.
    View on Amazon
    Tech specs
    Maximum power450 W
    Working voltage (Vmp)38.3 V
    Working current (Imp)11.7 A
    Open-circuit voltage (Voc)45.9 V
    Short-circuit current (Isc)12.4 A
    CellsMonocrystalline N-type
    Folded size30.4 × 34.6 × 3.5 in
    Unfolded size121.9 × 34.6 × 0.8 in
    Weight29.5 lb
    Operating temperature−4°F to 140°F

    Figures from the maker's spec sheet; it gives no maximum series fuse.

    Suggested setups
    IntoWiring per inputVoltage(When cold)CurrentMax power(Per input)All inputsString fuse
    Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh)3 in seriesany 1 to 3 in series works151 V limit 165 V12.4 A limit 17 A1,350 W2,700 W 6 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh)3 in seriesany 1 to 3 in series works157 V limit 165 V12.4 A limit 17 A1,350 W2,700 W 6 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh)3 in seriesany 1 to 3 in series works162 V limit 165 V12.4 A limit 17 A1,350 W2,700 W 6 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh)2 in seriesany 1 to 2 in series works111 V limit 165 V12.4 A limit 17 A900 W1,800 W 4 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh)2 in seriesany 1 to 2 in series works115 V limit 165 V12.4 A limit 17 A900 W1,800 W 4 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    EG4 6000XP off-grid inverter (6,000 W, 120/240 V)9 in seriesany 4 to 9 in series works454 V limit 480 V12.4 A limit 25 A4,000 W8,000 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    EG4 6000XP off-grid inverter (6,000 W, 120/240 V)9 in seriesany 4 to 9 in series works471 V limit 480 V12.4 A limit 25 A4,000 W8,000 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    EG4 6000XP off-grid inverter (6,000 W, 120/240 V)8 in seriesany 4 to 8 in series works433 V limit 480 V12.4 A limit 25 A3,600 W7,200 W 16 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    EG4 6000XP off-grid inverter (6,000 W, 120/240 V)8 in seriesany 4 to 8 in series works444 V limit 480 V12.4 A limit 25 A3,600 W7,200 W 16 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    EG4 6000XP off-grid inverter (6,000 W, 120/240 V)8 in seriesany 4 to 8 in series works459 V limit 480 V12.4 A limit 25 A3,600 W7,200 W 16 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    SunGold Power 10,000 W split-phase solar inverter (SPH10048P)9 in seriesany 4 to 9 in series works454 V limit 500 V12.4 A limit 22 A4,050 W8,100 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    SunGold Power 10,000 W split-phase solar inverter (SPH10048P)9 in seriesany 4 to 9 in series works471 V limit 500 V12.4 A limit 22 A4,050 W8,100 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    SunGold Power 10,000 W split-phase solar inverter (SPH10048P)9 in seriesany 4 to 9 in series works487 V limit 500 V12.4 A limit 22 A4,050 W8,100 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    SunGold Power 10,000 W split-phase solar inverter (SPH10048P)9 in seriesany 4 to 9 in series works500 V limit 500 V12.4 A limit 22 A4,050 W8,100 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    SunGold Power 10,000 W split-phase solar inverter (SPH10048P)8 in seriesany 4 to 8 in series works459 V limit 500 V12.4 A limit 22 A3,600 W7,200 W 16 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    Victron SmartSolar MPPT 100/50 charge controller2 in parallel, joined with a 2-to-1 Y connector50 V limit 100 V24.8 A limit 60 A700 W700 W 2 panels, 1 inputNot neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A.
    Victron SmartSolar MPPT 100/50 charge controller2 in parallel, joined with a 2-to-1 Y connector52 V limit 100 V24.8 A limit 60 A700 W700 W 2 panels, 1 inputNot neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A.
    Victron SmartSolar MPPT 100/50 charge controller2 in parallel, joined with a 2-to-1 Y connector54 V limit 100 V24.8 A limit 60 A700 W700 W 2 panels, 1 inputNot neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A.
    Victron SmartSolar MPPT 100/50 charge controller2 in parallel, joined with a 2-to-1 Y connector56 V limit 100 V24.8 A limit 60 A700 W700 W 2 panels, 1 inputNot neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A.
    Victron SmartSolar MPPT 100/50 charge controller2 in parallel, joined with a 2-to-1 Y connector57 V limit 100 V24.8 A limit 60 A700 W700 W 2 panels, 1 inputNot neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A.

    Worked out from the figures under Tech specs, with the cold-weather voltage factors of NEC Table 690.7(A). Too much voltage can destroy a power station or inverter: stay under the limit, and use one model of panel in each string.

  4. Tariff from Dec 4

    A lighter, bifacial version of the ZOUPW 450 W portable panel: it also catches light reflected onto its back.

    Explanation

    Largely the same as the ZOUPW 450W above, but about 30% lighter and more resilient to shade. In general it would be more reliable if your solar input capacity is limited, as on portable power stations. Whether that's worth the higher price is up to you.

    View on Amazon
    Tech specs
    Maximum power450 W
    Working voltage (Vmp)40 V
    Working current (Imp)11.7 A
    Open-circuit voltage (Voc)46 V
    Short-circuit current (Isc)12.4 A
    CellsMonocrystalline N-type, bifacial
    Folded size30.4 × 34.6 × 3.5 in
    Unfolded size121.9 × 34.6 × 0.9 in
    Weight20.9 lb
    Operating temperature−4°F to 140°F

    Figures from the maker's spec sheet; it gives no maximum series fuse.

    Suggested setups
    IntoWiring per inputVoltage(When cold)CurrentMax power(Per input)All inputsString fuse
    Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh)3 in seriesany 1 to 3 in series works152 V limit 165 V12.4 A limit 17 A1,350 W2,700 W 6 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh)3 in seriesany 1 to 3 in series works157 V limit 165 V12.4 A limit 17 A1,350 W2,700 W 6 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh)3 in seriesany 1 to 3 in series works163 V limit 165 V12.4 A limit 17 A1,350 W2,700 W 6 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh)2 in seriesany 1 to 2 in series works111 V limit 165 V12.4 A limit 17 A900 W1,800 W 4 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    Anker SOLIX F3800 Plus power station with Double Power Hub (7,680 Wh)2 in seriesany 1 to 2 in series works115 V limit 165 V12.4 A limit 17 A900 W1,800 W 4 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    EG4 6000XP off-grid inverter (6,000 W, 120/240 V)9 in seriesany 3 to 9 in series works455 V limit 480 V12.4 A limit 25 A4,000 W8,000 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    EG4 6000XP off-grid inverter (6,000 W, 120/240 V)9 in seriesany 3 to 9 in series works472 V limit 480 V12.4 A limit 25 A4,000 W8,000 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    EG4 6000XP off-grid inverter (6,000 W, 120/240 V)8 in seriesany 3 to 8 in series works434 V limit 480 V12.4 A limit 25 A3,600 W7,200 W 16 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    EG4 6000XP off-grid inverter (6,000 W, 120/240 V)8 in seriesany 3 to 8 in series works445 V limit 480 V12.4 A limit 25 A3,600 W7,200 W 16 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    EG4 6000XP off-grid inverter (6,000 W, 120/240 V)8 in seriesany 3 to 8 in series works460 V limit 480 V12.4 A limit 25 A3,600 W7,200 W 16 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    SunGold Power 10,000 W split-phase solar inverter (SPH10048P)9 in seriesany 4 to 9 in series works455 V limit 500 V12.4 A limit 22 A4,050 W8,100 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    SunGold Power 10,000 W split-phase solar inverter (SPH10048P)9 in seriesany 4 to 9 in series works472 V limit 500 V12.4 A limit 22 A4,050 W8,100 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    SunGold Power 10,000 W split-phase solar inverter (SPH10048P)9 in seriesany 4 to 9 in series works489 V limit 500 V12.4 A limit 22 A4,050 W8,100 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    SunGold Power 10,000 W split-phase solar inverter (SPH10048P)8 in seriesany 4 to 8 in series works445 V limit 500 V12.4 A limit 22 A3,600 W7,200 W 16 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    SunGold Power 10,000 W split-phase solar inverter (SPH10048P)8 in seriesany 4 to 8 in series works460 V limit 500 V12.4 A limit 22 A3,600 W7,200 W 16 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    Victron SmartSolar MPPT 100/50 charge controller2 in parallel, joined with a 2-to-1 Y connector51 V limit 100 V24.8 A limit 60 A700 W700 W 2 panels, 1 inputNot neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A.
    Victron SmartSolar MPPT 100/50 charge controller2 in parallel, joined with a 2-to-1 Y connector52 V limit 100 V24.8 A limit 60 A700 W700 W 2 panels, 1 inputNot neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A.
    Victron SmartSolar MPPT 100/50 charge controller2 in parallel, joined with a 2-to-1 Y connector54 V limit 100 V24.8 A limit 60 A700 W700 W 2 panels, 1 inputNot neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A.
    Victron SmartSolar MPPT 100/50 charge controller2 in parallel, joined with a 2-to-1 Y connector56 V limit 100 V24.8 A limit 60 A700 W700 W 2 panels, 1 inputNot neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A.
    Victron SmartSolar MPPT 100/50 charge controller2 in parallel, joined with a 2-to-1 Y connector58 V limit 100 V24.8 A limit 60 A700 W700 W 2 panels, 1 inputNot neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A.

    Worked out from the figures under Tech specs, with the cold-weather voltage factors of NEC Table 690.7(A). Too much voltage can destroy a power station or inverter: stay under the limit, and use one model of panel in each string.

Connection

String fuses are needed only where three or more strings of panels join in parallel on one solar input, as in large arrays wired through a combiner box. None of the setups on this page need them; each panel's Suggested setups says when one does. Separately, an inverter wired to its own battery, like the EG4 or the Victron 12/1200, needs a fuse or breaker on the battery cable; all-in-one power stations have this built in.

  1. A 60 A DC breaker in a weatherproof box that protects the charge controller's battery cable and switches it off.

    Explanation
    • Goes on the battery cable of a Victron SmartSolar 100/50 charge controller, which Victron says needs a 55 to 70 A fuse or breaker there.
    • Run the controller's positive through one pole and its negative through the other, so switching it off disconnects the controller completely. It isn't polarized, so either side can face the battery.
    View on Amazon
    Tech specs
    Rating60 A, 2 poles, 12 to 400 V DC, C trip curve
    Breaking capacity4 kA (the listing also gives 6 kA)
    Cable entryIP68 glands for 4 to 9 mm cable (11 to 5 AWG); crimp ferrules included

    Figures from the Amazon listing.

  2. Y connectors that join the cables from two panels into one line.

    View on Amazon
    Tech specs
    Rated current30 A
    Rated voltage1,000 V DC
    Cable14 to 10 AWG
    Pairs4 (each: one 1-male-to-2-female, one 1-female-to-2-male)
    WeatherproofingIP68

    Figures from the Amazon listing.

  3. Outdoor-rated solar cable for running power from the panels to a charge controller, inverter or power station.

    View on Amazon
    Tech specs
    Gauge10 AWG (6 mm²)
    ConductorTinned copper, 84 strands
    Voltage rating1,800 V DC
    StandardsTÜV, IEC 62930

    Figures from the Amazon listing.

Batteries

  1. Rebate ends Jan 1

    An all-in-one battery backup: battery, 120/240 V inverter and solar charging in one unit, 7,680 Wh in this kit per the listing.

    Explanation

    If you'd rather skip the extremely complicated job of building a battery backup system out of raw components, get this all-in-one kit.

    View on Amazon
    Tech specs
    Solar inputs2 per F3800 Plus unit
    Input voltage11–165 V; never above 165 V open-circuit
    Current per input17 A
    Power per input1,600 W
    Battery3,840 Wh LiFePO4 per unit; 7,680 Wh for this kit per the listing
    ExpansionUp to 26.9 kWh per unit with 6 expansion batteries
    AC output6,000 W, 120 V and 240 V, per unit
    Solar3,200 W per unit
    AC charging1,800 W per unit
    UPS switchover20 ms
    Idle drawAbout 30 to 40 W with the AC outlets on and nothing plugged in, so 0.7 to 1 kWh a day (PCMag, 2026). Before Anker's mid-2025 firmware update reviewers saw 50 to 70 W; Anker says the update halved it
    Cycle life3,000+ cycles to 80%
    Operating temperatureDischarges −4 to 104°F, charges 32 to 104°F
    Weight136.7 lb per unit; 27.6 × 15.3 × 15.6 in

    Figures from the Amazon listing and Anker's F3800 Plus page; idle draw from PCMag's 2026 review and How-To Geek (Anker publishes no figure).

    Suggested setups
    PanelWiring per inputVoltage(When cold)CurrentMax power(Per input)All inputsString fuse
    HQST 200W N-Type solar panel6 in seriesany 1 to 6 in series works148 V limit 165 V11 A limit 17 A1,200 W2,400 W 12 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    HQST 200W N-Type solar panel6 in seriesany 1 to 6 in series works153 V limit 165 V11 A limit 17 A1,200 W2,400 W 12 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    HQST 200W N-Type solar panel6 in seriesany 1 to 6 in series works159 V limit 165 V11 A limit 17 A1,200 W2,400 W 12 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    HQST 200W N-Type solar panel6 in seriesany 1 to 6 in series works163 V limit 165 V11 A limit 17 A1,200 W2,400 W 12 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    HQST 200W N-Type solar panel5 in seriesany 1 to 5 in series works140 V limit 165 V11 A limit 17 A1,000 W2,000 W 10 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    Renogy 200W N-Type solar panels (4-pack, 800 W)2 strings of 4 in series, joined with a 2-to-1 Y connector165 V limit 165 V13.7 A limit 17 A1,600 W3,200 W 16 panels, 2 inputs per F3800 Plus unitNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    Renogy 200W N-Type solar panels (4-pack, 800 W)2 strings of 3 in series, joined with a 2-to-1 Y connector128 V limit 165 V13.7 A limit 17 A1,200 W2,400 W 12 panels, 2 inputs per F3800 Plus unitNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    Renogy 200W N-Type solar panels (4-pack, 800 W)2 strings of 3 in series, joined with a 2-to-1 Y connector133 V limit 165 V13.7 A limit 17 A1,200 W2,400 W 12 panels, 2 inputs per F3800 Plus unitNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    Renogy 200W N-Type solar panels (4-pack, 800 W)2 strings of 3 in series, joined with a 2-to-1 Y connector136 V limit 165 V13.7 A limit 17 A1,200 W2,400 W 12 panels, 2 inputs per F3800 Plus unitNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    Renogy 200W N-Type solar panels (4-pack, 800 W)2 strings of 3 in series, joined with a 2-to-1 Y connector140 V limit 165 V13.7 A limit 17 A1,200 W2,400 W 12 panels, 2 inputs per F3800 Plus unitNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    ZOUPW 450W portable solar panel3 in seriesany 1 to 3 in series works151 V limit 165 V12.4 A limit 17 A1,350 W2,700 W 6 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W portable solar panel3 in seriesany 1 to 3 in series works157 V limit 165 V12.4 A limit 17 A1,350 W2,700 W 6 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W portable solar panel3 in seriesany 1 to 3 in series works162 V limit 165 V12.4 A limit 17 A1,350 W2,700 W 6 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W portable solar panel2 in seriesany 1 to 2 in series works111 V limit 165 V12.4 A limit 17 A900 W1,800 W 4 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W portable solar panel2 in seriesany 1 to 2 in series works115 V limit 165 V12.4 A limit 17 A900 W1,800 W 4 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W PRO bifacial portable solar panel3 in seriesany 1 to 3 in series works152 V limit 165 V12.4 A limit 17 A1,350 W2,700 W 6 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W PRO bifacial portable solar panel3 in seriesany 1 to 3 in series works157 V limit 165 V12.4 A limit 17 A1,350 W2,700 W 6 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W PRO bifacial portable solar panel3 in seriesany 1 to 3 in series works163 V limit 165 V12.4 A limit 17 A1,350 W2,700 W 6 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W PRO bifacial portable solar panel2 in seriesany 1 to 2 in series works111 V limit 165 V12.4 A limit 17 A900 W1,800 W 4 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W PRO bifacial portable solar panel2 in seriesany 1 to 2 in series works115 V limit 165 V12.4 A limit 17 A900 W1,800 W 4 panels, 2 inputs per F3800 Plus unitNot neededOne string can't overload itself. If you add one anyway: 20 A.

    Worked out from the figures under Tech specs, with the cold-weather voltage factors of NEC Table 690.7(A). Too much voltage can destroy a power station or inverter: stay under the limit, and use one model of panel in each string.

  2. Rebate ends Jan 1

    A 12 V lithium (LiFePO4) battery that stores 3,584 Wh: the heart of the small battery station.

    Explanation
    • With the Victron inverter and charge controller, this makes a small, cheap battery station that keeps a fridge or freezer running through an outage.
    • To see how long it lasts, find your fridge's yearly kWh on its yellow EnergyGuide label, divide by 365 for a day's use, and add about a quarter of a kWh a day for the inverter.
    • Keep it indoors: it stops charging in the cold to protect itself.
    View on Amazon
    Tech specs
    Battery280 Ah at 12.8 V, 3,584 Wh LiFePO4
    BMS200 A, stops charging at low temperatures
    MonitoringBluetooth app
    CaseMetal, with mounting feet; no battery box needed
    Charge settings14.6 V absorption; float off, or 13.8 V if it can't be turned off; no equalization
    Warranty3 years
    Safety switchCuts the discharge circuit
    Idle drawNot published (BMS and Bluetooth)

    Figures from the Amazon listing.

  3. Rebate ends Jan 1

    A 48 V lithium (LiFePO4) server-rack battery that stores 5,120 Wh, for a 48 V inverter such as the EG4.

    How to use it: 10 kW hand truck power station
    View on Amazon
    Tech specs
    Battery100 Ah at 51.2 V, 5,120 Wh LiFePO4
    ExpansionUp to 32 in parallel (163.8 kWh)
    Inverter communicationCAN and RS485 (closed loop)
    MonitoringBluetooth and Wi-Fi app
    CertificationsUL9540, UL9540A, UL1973, CEC listed
    IncludedParallel, communication and grounding cables, terminal covers, screws
    Size and weight22.09 × 19.02 × 5.63 in, 103 lb; fits a server rack
    Warranty10 years
    Idle drawNot published (BMS, Bluetooth and Wi-Fi)

    Figures from the Amazon listing.

  4. Keeps 12 V batteries wired in series (to make 24, 36 or 48 V) all at the same charge.

    Explanation

    That way none of them is overcharged or run too low.

    View on Amazon
    Tech specs
    Bank12 V batteries wired in series to 24, 36 or 48 V
    Balancing currentUp to 10 A
    Balances untilBatteries are within 10 mV of each other
    Battery typesLiFePO4, lithium-ion, lead-acid (AGM, gel, flooded)
    ProtectionReverse polarity, high temperature
    Idle drawUnder 5 mA once the batteries are within 10 mV

    Figures from the Amazon listing.

Inverters and charge controllers

  1. A 6,000 W off-grid inverter that charges a battery bank from solar and turns its power into 120/240 V household power.

    Explanation
    • Shove as much voltage into it as you can: wire panels in long series strings, up to its 480 V limit. Suggested setups works out how many of each panel.
    • It needs a separate 48 V battery bank.
    View at Signature Solar
    Tech specs
    Solar inputs2
    Input voltage100–480 V; never above 480 V open-circuit
    Full-power voltage120–385 V
    Current per input17 A usable; short-circuit up to 25 A
    Power per input4,000 W
    AC output6,000 W, 120/240 V split phase
    Surge12 kW for about 3.5 seconds
    Battery48 V, not included; over 200 Ah recommended
    Battery currentCharges at up to 125 A, discharges at up to 140 A
    Solar8,000 W used (4,000 W per input); start-up at 100 V
    Generator or grid inputUp to 9,000 W
    ExpansionUp to 16 units in parallel
    Idle drawAbout 50 W on battery, under 50 W on grid, under 30 W running from solar (EG4's figures, measured with a steady 300 V solar input); about 1.2 kWh a day on battery

    Figures from EG4's 6000XP spec sheet (version 1.2.1) and Signature Solar's product page.

    Suggested setups
    PanelWiring per inputVoltage(When cold)CurrentMax power(Per input)All inputsString fuse
    HQST 200W N-Type solar panel19 in seriesany 7 to 19 in series works468 V limit 480 V11 A limit 25 A3,800 W7,600 W 38 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    HQST 200W N-Type solar panel18 in seriesany 7 to 18 in series works460 V limit 480 V11 A limit 25 A3,600 W7,200 W 36 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    HQST 200W N-Type solar panel18 in seriesany 7 to 18 in series works476 V limit 480 V11 A limit 25 A3,600 W7,200 W 36 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    HQST 200W N-Type solar panel17 in seriesany 7 to 17 in series works461 V limit 480 V11 A limit 25 A3,400 W6,800 W 34 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    HQST 200W N-Type solar panel17 in seriesany 7 to 17 in series works476 V limit 480 V11 A limit 25 A3,400 W6,800 W 34 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    Renogy 200W N-Type solar panels (4-pack, 800 W)2 strings of 10 in series, joined with a 2-to-1 Y connector412 V limit 480 V13.7 A limit 25 A4,000 W8,000 W 40 panels, 2 inputsNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    Renogy 200W N-Type solar panels (4-pack, 800 W)2 strings of 10 in series, joined with a 2-to-1 Y connector427 V limit 480 V13.7 A limit 25 A4,000 W8,000 W 40 panels, 2 inputsNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    Renogy 200W N-Type solar panels (4-pack, 800 W)2 strings of 10 in series, joined with a 2-to-1 Y connector442 V limit 480 V13.7 A limit 25 A4,000 W8,000 W 40 panels, 2 inputsNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    Renogy 200W N-Type solar panels (4-pack, 800 W)2 strings of 10 in series, joined with a 2-to-1 Y connector453 V limit 480 V13.7 A limit 25 A4,000 W8,000 W 40 panels, 2 inputsNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    Renogy 200W N-Type solar panels (4-pack, 800 W)2 strings of 10 in series, joined with a 2-to-1 Y connector468 V limit 480 V13.7 A limit 25 A4,000 W8,000 W 40 panels, 2 inputsNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    ZOUPW 450W portable solar panel9 in seriesany 4 to 9 in series works454 V limit 480 V12.4 A limit 25 A4,000 W8,000 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W portable solar panel9 in seriesany 4 to 9 in series works471 V limit 480 V12.4 A limit 25 A4,000 W8,000 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W portable solar panel8 in seriesany 4 to 8 in series works433 V limit 480 V12.4 A limit 25 A3,600 W7,200 W 16 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W portable solar panel8 in seriesany 4 to 8 in series works444 V limit 480 V12.4 A limit 25 A3,600 W7,200 W 16 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W portable solar panel8 in seriesany 4 to 8 in series works459 V limit 480 V12.4 A limit 25 A3,600 W7,200 W 16 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W PRO bifacial portable solar panel9 in seriesany 3 to 9 in series works455 V limit 480 V12.4 A limit 25 A4,000 W8,000 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W PRO bifacial portable solar panel9 in seriesany 3 to 9 in series works472 V limit 480 V12.4 A limit 25 A4,000 W8,000 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W PRO bifacial portable solar panel8 in seriesany 3 to 8 in series works434 V limit 480 V12.4 A limit 25 A3,600 W7,200 W 16 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W PRO bifacial portable solar panel8 in seriesany 3 to 8 in series works445 V limit 480 V12.4 A limit 25 A3,600 W7,200 W 16 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W PRO bifacial portable solar panel8 in seriesany 3 to 8 in series works460 V limit 480 V12.4 A limit 25 A3,600 W7,200 W 16 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.

    Worked out from the figures under Tech specs, with the cold-weather voltage factors of NEC Table 690.7(A). Too much voltage can destroy a power station or inverter: stay under the limit, and use one model of panel in each string.

  2. An inverter that turns a 12 V battery's power into 120 V household power, up to 1,000 W, while idling at only about 10 W.

    Explanation
    • A fridge's compressor runs only part of the time, but an inverter draws power around the clock, so its idle draw matters as much as its size. Its 2,200 W peak starts a fridge or freezer compressor.
    • It runs 1,000 W continuously: enough for a fridge or freezer and small loads, not heaters or microwaves.
    • It runs from a 12 V battery like the ECO-WORTHY, with the Go Power Class T fuse on its battery cable.
    View on Amazon
    Tech specs
    AC output1,200 VA: 1,000 W continuous at 77°F, 850 W at 104°F; 120 V, one NEMA 5-15R GFCI outlet
    Peak2,200 W
    Idle draw10 W (11 W in Victron's 2026 120 V manual), about 0.25 kWh a day; 1 W in ECO mode
    Battery12 V (9.2 to 17 V)

    Figures from Victron's Phoenix Inverter VE.Direct 250VA to 1200VA datasheet (the listing's bullet points give the smaller 800 VA model's figures); the 11 W from Victron's Inverter VE.Direct 120V manual (2026).

  3. A solar charge controller: it charges a 12 V battery like the ECO-WORTHY from solar panels.

    Explanation
    • It takes up to 100 V, so panels go in short strings; on a 12 V battery it delivers up to 700 W, and panels beyond that are simply capped. Suggested setups works out how many of each panel.
    • In its app, choose the LiFePO4 battery setting.
    View on Amazon
    Tech specs
    Solar inputs1
    Input voltage20–100 V; never above 100 V open-circuit
    Current per input60 A usable; short-circuit up to 60 A
    Power per input700 W
    Battery12 or 24 V, detected automatically
    Charge current50 A
    Solar700 W at 12 V, 1,400 W at 24 V; more panels are capped
    Solar inputUp to 100 V open circuit and 60 A short circuit; starts once panels reach battery voltage plus 5 V
    Idle draw30 mA at 12 V (about 0.4 W)
    Operating temperature−22 to 140°F; full output up to 104°F

    Figures from Victron's SmartSolar MPPT 100/30 and 100/50 datasheet.

    Suggested setups
    PanelWiring per inputVoltage(When cold)CurrentMax power(Per input)All inputsString fuse
    HQST 200W N-Type solar panel4 in seriesany 2 to 4 in series works99 V limit 100 V11 A limit 60 A700 W700 W 4 panels, 1 inputNot neededOne string can't overload itself. If you add one anyway: 20 A.
    HQST 200W N-Type solar panel2 strings of 2 in series, joined with a 2-to-1 Y connector51 V limit 100 V22.1 A limit 60 A700 W700 W 4 panels, 1 inputNot neededThe other string can feed at most 14 A, within the panel's 20 A rating. If you add one anyway: 20 A.
    HQST 200W N-Type solar panel2 strings of 2 in series, joined with a 2-to-1 Y connector53 V limit 100 V22.1 A limit 60 A700 W700 W 4 panels, 1 inputNot neededThe other string can feed at most 14 A, within the panel's 20 A rating. If you add one anyway: 20 A.
    HQST 200W N-Type solar panel2 strings of 2 in series, joined with a 2-to-1 Y connector54 V limit 100 V22.1 A limit 60 A700 W700 W 4 panels, 1 inputNot neededThe other string can feed at most 14 A, within the panel's 20 A rating. If you add one anyway: 20 A.
    HQST 200W N-Type solar panel2 strings of 2 in series, joined with a 2-to-1 Y connector56 V limit 100 V22.1 A limit 60 A700 W700 W 4 panels, 1 inputNot neededThe other string can feed at most 14 A, within the panel's 20 A rating. If you add one anyway: 20 A.
    Renogy 200W N-Type solar panels (4-pack, 800 W)2 strings of 2 in series, joined with a 2-to-1 Y connector82 V limit 100 V13.7 A limit 60 A700 W700 W 4 panels, 1 inputNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    Renogy 200W N-Type solar panels (4-pack, 800 W)2 strings of 2 in series, joined with a 2-to-1 Y connector85 V limit 100 V13.7 A limit 60 A700 W700 W 4 panels, 1 inputNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    Renogy 200W N-Type solar panels (4-pack, 800 W)2 strings of 2 in series, joined with a 2-to-1 Y connector88 V limit 100 V13.7 A limit 60 A700 W700 W 4 panels, 1 inputNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    Renogy 200W N-Type solar panels (4-pack, 800 W)2 strings of 2 in series, joined with a 2-to-1 Y connector91 V limit 100 V13.7 A limit 60 A700 W700 W 4 panels, 1 inputNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    Renogy 200W N-Type solar panels (4-pack, 800 W)2 strings of 2 in series, joined with a 2-to-1 Y connector94 V limit 100 V13.7 A limit 60 A700 W700 W 4 panels, 1 inputNot neededThe other string can feed at most 9 A, within the panel's 15 A rating. If you add one anyway: 15 A.
    ZOUPW 450W portable solar panel2 in parallel, joined with a 2-to-1 Y connector50 V limit 100 V24.8 A limit 60 A700 W700 W 2 panels, 1 inputNot neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A.
    ZOUPW 450W portable solar panel2 in parallel, joined with a 2-to-1 Y connector52 V limit 100 V24.8 A limit 60 A700 W700 W 2 panels, 1 inputNot neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A.
    ZOUPW 450W portable solar panel2 in parallel, joined with a 2-to-1 Y connector54 V limit 100 V24.8 A limit 60 A700 W700 W 2 panels, 1 inputNot neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A.
    ZOUPW 450W portable solar panel2 in parallel, joined with a 2-to-1 Y connector56 V limit 100 V24.8 A limit 60 A700 W700 W 2 panels, 1 inputNot neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A.
    ZOUPW 450W portable solar panel2 in parallel, joined with a 2-to-1 Y connector57 V limit 100 V24.8 A limit 60 A700 W700 W 2 panels, 1 inputNot neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A.
    ZOUPW 450W PRO bifacial portable solar panel2 in parallel, joined with a 2-to-1 Y connector51 V limit 100 V24.8 A limit 60 A700 W700 W 2 panels, 1 inputNot neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A.
    ZOUPW 450W PRO bifacial portable solar panel2 in parallel, joined with a 2-to-1 Y connector52 V limit 100 V24.8 A limit 60 A700 W700 W 2 panels, 1 inputNot neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A.
    ZOUPW 450W PRO bifacial portable solar panel2 in parallel, joined with a 2-to-1 Y connector54 V limit 100 V24.8 A limit 60 A700 W700 W 2 panels, 1 inputNot neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A.
    ZOUPW 450W PRO bifacial portable solar panel2 in parallel, joined with a 2-to-1 Y connector56 V limit 100 V24.8 A limit 60 A700 W700 W 2 panels, 1 inputNot neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A.
    ZOUPW 450W PRO bifacial portable solar panel2 in parallel, joined with a 2-to-1 Y connector58 V limit 100 V24.8 A limit 60 A700 W700 W 2 panels, 1 inputNot neededCheck the panel label: needed if its maximum series fuse is below 16 A. If you add one anyway: 20 A.

    Worked out from the figures under Tech specs, with the cold-weather voltage factors of NEC Table 690.7(A). Too much voltage can destroy a power station or inverter: stay under the limit, and use one model of panel in each string.

Accessories

  1. A surge protector for the solar lines of a power station or portable setup: it sends surges from nearby lightning to ground.

    Explanation
    • Lightning doesn't have to hit your panels to fry your charge controller or power station: a strike nearby induces a surge in the long wires from the panels, and this sends it to ground. It won't save anything from a direct hit.
    • This 300 V version is for portable and power station setups; for inverter setups like the EG4, whose panel strings run up to 480 V, get the 600 V version below.
    • You need one for each solar line going into your charge controller or power station, mounted right next to it, plus a second one at the panel end if that wire run is longer than about 30 feet.
    • It only works wired with short, straight leads to a proper ground rod.
    • Panels set out on the ground beside a power station on a short cable don't need one.
    • Its blue lights go out at night; if they're out while the sun is up, replace it.
    View on Amazon
    Tech specs
    System voltageUp to 300 V DC
    Status lightsBlue when voltage is present; off at night is normal
    EnclosureType 4X, outdoor
    Size and weight4.4 × 3.8 × 3.5 in, 1 lb
    Warranty5 years

    Figures from the Amazon listing and MidNite's installation manual.

  2. The same surge protector in a 600 V version, for inverter setups like the EG4.

    Explanation

    The EG4's panel strings run up to 480 V, too high for the 300 V version. Everything in the 300 V version's explanation applies: one for each solar input at the inverter, plus one at the panel end of runs longer than about 30 feet, wired with short, straight leads to a proper ground rod.

    View on Amazon
    Tech specs
    System voltageUp to 600 V DC
    Status lightsLit when voltage is present between DC+ and DC−; off at night is normal
    Weight13.4 oz

    Figures from the Amazon listing and MidNite's installation manual.

  3. A weatherproof on/off switch that disconnects two solar panel lines from whatever they feed.

    View on Amazon
    Tech specs
    Poles4: two lines in and two out
    Rated voltage1,500 V DC
    Rated current32 A per pole
    Connectors4 MC4
    EnclosureIP66

    Figures from the Amazon listing.

  4. A cable that connects a Victron Phoenix inverter to a computer, to change its settings.

    Explanation

    The Victron Phoenix inverters have no Bluetooth. This cable connects one to a computer running Victron's free VictronConnect app, to change settings such as raising the low-battery shutdown.

    View on Amazon
    Tech specs
    UseConnects a VE.Direct port (the Phoenix inverter, the SmartSolar controller) to a computer's USB port for VictronConnect, or adds VE.Direct devices to a Victron GX device
    Part numberASS030530010
    Warranty5 years

    Figures from the Amazon listing.

10 kW hand truck build

The parts for Will Prowse's 10 kW hand truck: a 120/240 V solar power system with 10 kWh of battery on a hand truck. It also uses two ECO-WORTHY Cubix 100 batteries, listed under Batteries. The guide '10 kW hand truck power station' has the whole build and a link to Will's step-by-step page.

  1. A red and a black 20 ft, 10 AWG solar cable with MC4 connectors.

    Explanation

    Optional on the 10 kW hand truck: use it if your panel leads don't reach the PV disconnect.

    How to use it: 10 kW hand truck power station
    View on Amazon
  2. Heavy-duty hand cutters for copper cable.

    Explanation

    Cuts the NEMA 14-50 cord and the 6 AWG THHN for the 10 kW hand truck.

    How to use it: 10 kW hand truck power station
    View on Amazon
  3. Battery cables made to the length you order, with lugs crimped on both ends.

    Explanation

    The 10 kW hand truck needs four in 2/0 AWG with 5/16 in (M8) lugs on both ends: red 2 ft and black 2 ft from the batteries to the inverter, and a red 1 ft and a black 1 ft jumper between the two batteries.

    How to use it: 10 kW hand truck power station
    View at Current Connected
  4. A steel hand truck rated for 1,000 lb, with a wide toe plate and flat-free tires.

    Explanation

    The frame of the 10 kW hand truck. Both batteries stand upright on the toe plate with a ratchet strap around them, the outlet box screws to the frame above them and the inverter to the back. The finished gear weighs about 270 lb.

    How to use it: 10 kW hand truck power station
    View at Home Depot
  5. A ratchet crimper with a hex die and a box of ferrules in 17 sizes.

    Explanation

    A ferrule turns stranded wire into one solid pin that a screw terminal can grip. On the 10 kW hand truck one goes on every stranded wire into a screw terminal: the AC input cord, the AC output wires to the outlet box and the two PV wires.

    How to use it: 10 kW hand truck power station
    View on Amazon
  6. A wire stripper that adjusts itself to wire from 10 to 24 AWG.

    Explanation

    Strips the NEMA 14-50 cord and the 10 AWG PV wire for the 10 kW hand truck.

    How to use it: 10 kW hand truck power station
    View on Amazon
  7. A 3 ft 50 A plug cord with open wire ends, for hardwiring a 240 V input.

    Explanation

    Optional on the 10 kW hand truck: it connects the inverter's AC input to a 240 V, 4-wire source (a 14-50 outlet or a generator) for charging.

    How to use it: 10 kW hand truck power station
    View on Amazon
  8. A 30 A, 2-pole DC breaker in a weatherproof box that switches a solar string off, with short MC4 leads.

    Explanation

    Each solar string on the 10 kW hand truck runs through its own disconnect to the inverter; a second string needs a second one.

    How to use it: 10 kW hand truck power station
    View on Amazon
  9. A weatherproof box with a 50 A 14-50R, a 30 A TT-30R and 20 A 5-20R outlets, each on its own breaker.

    Explanation

    Takes the place of a load panel on the 10 kW hand truck: wired to the inverter's AC output, it gives 240 V for a well pump, dryer, 50 A RV or EV charger, plus 120 V outlets.

    How to use it: 10 kW hand truck power station
    View on Amazon
  10. An assortment of hex-head self-drilling screws for sheet metal, 1/2 in to 1-1/4 in.

    Explanation

    Mounts the inverter bracket, the outlet box and the PV disconnect to the hand truck frame.

    How to use it: 10 kW hand truck power station
    View on Amazon
  11. A 48 V all-in-one inverter: inverter, two solar charge controllers and a battery charger in one box, putting out 120 V on each leg and 240 V across both.

    Explanation
    • The heart of Will Prowse's 10 kW hand truck. It screws to the back of the hand truck frame, over the wheels.
    • It needs at least 125 V on each solar input to charge, so panels go in series. It takes a 240 V, 4-wire source (NEMA 14-50) on its AC input; a 120 V source gives a fault.
    How to use it: 10 kW hand truck power station
    View on Amazon
    Tech specs
    Solar inputs2
    Input voltage125–500 V; never above 500 V open-circuit
    Full-power voltage125–425 V
    Current per input22 A
    Power per input5,000 W
    AC output10,000 W, 120/240 V split phase; 20,000 W peak, rated for 6 HP motors
    SolarTwo inputs, 10,000 W together, up to 22 A each; 125 to 425 V working range, 500 V open-circuit maximum
    Battery48 V, not included; charges at up to 200 A
    WeightAbout 54 to 60 lb

    Figures from Will Prowse's build page and the Amazon listing.

    Suggested setups
    PanelWiring per inputVoltage(When cold)CurrentMax power(Per input)All inputsString fuse
    HQST 200W N-Type solar panel20 in seriesany 7 to 20 in series works493 V limit 500 V11 A limit 22 A4,000 W8,000 W 40 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    HQST 200W N-Type solar panel19 in seriesany 7 to 19 in series works485 V limit 500 V11 A limit 22 A3,800 W7,600 W 38 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    HQST 200W N-Type solar panel18 in seriesany 7 to 18 in series works476 V limit 500 V11 A limit 22 A3,600 W7,200 W 36 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    HQST 200W N-Type solar panel18 in seriesany 7 to 18 in series works488 V limit 500 V11 A limit 22 A3,600 W7,200 W 36 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    HQST 200W N-Type solar panel17 in seriesany 7 to 17 in series works476 V limit 500 V11 A limit 22 A3,400 W6,800 W 34 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    Renogy 200W N-Type solar panels (4-pack, 800 W)3 strings of 9 in series, joined with a fuse on each string371 V limit 500 V20.5 A limit 22 A5,000 W10,000 W 54 panels, 2 inputs15 A on each stringThe other strings can overload a faulted one.
    Renogy 200W N-Type solar panels (4-pack, 800 W)3 strings of 9 in series, joined with a fuse on each string384 V limit 500 V20.5 A limit 22 A5,000 W10,000 W 54 panels, 2 inputs15 A on each stringThe other strings can overload a faulted one.
    Renogy 200W N-Type solar panels (4-pack, 800 W)3 strings of 9 in series, joined with a fuse on each string398 V limit 500 V20.5 A limit 22 A5,000 W10,000 W 54 panels, 2 inputs15 A on each stringThe other strings can overload a faulted one.
    Renogy 200W N-Type solar panels (4-pack, 800 W)3 strings of 9 in series, joined with a fuse on each string408 V limit 500 V20.5 A limit 22 A5,000 W10,000 W 54 panels, 2 inputs15 A on each stringThe other strings can overload a faulted one.
    Renogy 200W N-Type solar panels (4-pack, 800 W)3 strings of 9 in series, joined with a fuse on each string421 V limit 500 V20.5 A limit 22 A5,000 W10,000 W 54 panels, 2 inputs15 A on each stringThe other strings can overload a faulted one.
    ZOUPW 450W portable solar panel9 in seriesany 4 to 9 in series works454 V limit 500 V12.4 A limit 22 A4,050 W8,100 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W portable solar panel9 in seriesany 4 to 9 in series works471 V limit 500 V12.4 A limit 22 A4,050 W8,100 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W portable solar panel9 in seriesany 4 to 9 in series works487 V limit 500 V12.4 A limit 22 A4,050 W8,100 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W portable solar panel9 in seriesany 4 to 9 in series works500 V limit 500 V12.4 A limit 22 A4,050 W8,100 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W portable solar panel8 in seriesany 4 to 8 in series works459 V limit 500 V12.4 A limit 22 A3,600 W7,200 W 16 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W PRO bifacial portable solar panel9 in seriesany 4 to 9 in series works455 V limit 500 V12.4 A limit 22 A4,050 W8,100 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W PRO bifacial portable solar panel9 in seriesany 4 to 9 in series works472 V limit 500 V12.4 A limit 22 A4,050 W8,100 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W PRO bifacial portable solar panel9 in seriesany 4 to 9 in series works489 V limit 500 V12.4 A limit 22 A4,050 W8,100 W 18 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W PRO bifacial portable solar panel8 in seriesany 4 to 8 in series works445 V limit 500 V12.4 A limit 22 A3,600 W7,200 W 16 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.
    ZOUPW 450W PRO bifacial portable solar panel8 in seriesany 4 to 8 in series works460 V limit 500 V12.4 A limit 22 A3,600 W7,200 W 16 panels, 2 inputsNot neededOne string can't overload itself. If you add one anyway: 20 A.

    Worked out from the figures under Tech specs, with the cold-weather voltage factors of NEC Table 690.7(A). Too much voltage can destroy a power station or inverter: stay under the limit, and use one model of panel in each string.

  12. Four color-coded 5 ft lengths of stranded THHN building wire: three 6 AWG and a 10 AWG green ground.

    Explanation

    Connects the outlet box to the inverter's AC output on the 10 kW hand truck: black to L1, red to L2, white to neutral, green to ground.

    How to use it: 10 kW hand truck power station
    View on Amazon
    Tech specs
    Wires6 AWG black, red and white; 10 AWG green; 5 ft each
    Rating600 V, 19 strands

    Figures from the Amazon listing.